COWAY Airmega Jet AP-1220B Air Purifier

COWAY Airmega Jet AP-1220B Air Purifier with GreenHEPA technology - Removes 99.999% of harmful particles down to 0.01 µm*

COWAY Airmega Jet AP-1220B Air Purifier with GreenHEPA technology – Removes 99.999% of harmful particles down to 0.01 µm*, ECARF certified for allergy sufferers, Test winner by Testfakta

  • HyperCaptive FILTRATION: Filter system with a CADR of 402 m³/h removes up to 99.999 per cent of particles; Sufficient performance in rooms up to 104 m², intensive cleaning in rooms smaller than 41 m²
  • GreenHEPA TECHNOLOGY: Within 24 hours the air purifier captures and inactivates particles in the air, including allergens, bacteria, pet hair, dust, mould, odours, pollen, viruses and more
  • MegaJet TECHNOLOGY: 2 air modes include Normal mode, in which clean air flows upwards for quick air circulation in small areas and Focus mode for a wide range of air purification; fast cooling/heating
  • TESTFAKTA No. 1 (2020): The Coway Airmega Jet was awarded the test winner by the renowned Swedish Testfakta Institute out of 13 top air purifiers
  • COWAY: Specialists in air cleaning systems since 1994. We hold over 5,000 product patents and have already supplied more than 15 million customers with clean air worldwide

SKU: B08Z13YT8Q
Weight: 9.73 kg
Dimensions: 28.4 x 46.81 x 80.11 cm; 9.73 Kilograms
Brand: Coway
Model: AP-1220B
Colour: Silver
Colour: Silver

Product Description

dddmodule 3focus mode jeteng

Test Winner

Test winner: In December 2020, the Airmega Jet was named the test winner by the Swedish TestFakta Institute.

Auto mode: Thanks to the auto mode function, the Airmega Jet automatically adapts to its surroundings and adjusts the fan speed to the indoor air quality – for even more efficiency!

Sleep mode: The air purifier has a low energy consumption of a maximum of 50 watts and adapts automatically to the lighting conditions – at night it switches to “sleep mode” with a maximum of 20 dB and only 5.5 watts of power consumption.

coway jetereddhue & healing crossCoway Mighty crossd
Room Size ¹ 104 m² 73 m² 73 m² 64 m² 109 m² 149 m²
4 x air circulation (2.4 m high) 41 m² 29 m² 29 m² 25 m² 43 m² 59 m²
CADR (Clean Air Delivery Rate) ² 402 m³/h 281 m³/h 281 m³/h 247 m³/h 421 m³/h 575 m³/h
Filter Washable pre-filter + Activated carbon filter + GreenHEPA filter Washable pre-filter + Activated carbon filter + GreenHEPA filter Washable pre-filter + Activated carbon filter + GreenHEPA filter Washable pre-filter + Activated carbon filter + HEPA filter Washable pre-filter + Deodorization filter + GreenHepa filter Washable pre-filter + Max2 filter (Activated carbon filter + GreenHEPA filter)
Air Flow Control 3 Levels(Auto, Silent, Turbo, Normal, Focus, 1, 2,3) 2 Levels(Auto, Silent, 1, 2) 2 Levels(Auto, Silent, 1, 2) 3 Levels(Silent, Auto, Sleep, 1, 2 , 3) 3 Levels(Eco, Auto,1,2,3) 3 Levels(Sleep(Smart), Eco(Smart), Auto(Smart)1,2,3)
Power consumption 5.5 W – 50 W 5.1 W – 33.4 W 5.1 W – 33.4 W 6 – 48 W 3.7 W – 69.7 W 6.3 W – 54.4 W
Dimensions (L x W x H) 37.6 X 19.6 X 71.7 cm 34 X 16.5 X 46.9 cm 34 X 16.5 X 46.9 cm 41.7 X 27.2 X 51.5 cm 41 X 23 X 47 cm 34.5 X 34.5 X 53.2 cm
Weight 8.7 kg 5.5 kg 5.5 kg 10 kg 5.9 kg 9.7 kg
Colours Available White Dove White, Sage Green, Peony Pink Monstera, Oliveleaf, Navy White White, Black White
Awards ECARF ECARF, QUIET MARK ECARF, QUIET MARK QUIET MARK ECARF, BAF ECARF, QUIET MARK

* Coway air purifiers have been proven to trap dust, pollen, dander, viruses, and bacteria in the air based on KCL(Korea Conformity Laboratories) testing. They have been tested in a 30㎥ size chamber according to the Korea Air Cleaning Association standard (SPS-KACA 002-132:2018 Modified) to measure the 0.01㎛ size particle removal rate. It was tested on maximum fan speed in normal room temperature and humidity conditions. The performance may vary in the actual living environment of customers.

** 99.9% of viruses, bacteria, fungi, and pollen were verified to be removed from the air for Coway air purifiers which have a GreenHEPA filter applied based on the Japan Food Research Laboratories(JFRL) testing according to JEM 1467 standard. -Virus: Tested with Escherichia coli phage ΦX174 NBRC 103405, 60 minutes -Bacteria: Tested with Staphylococcus epidermidis NBRC 12993, 60 minutes -Fungi/Mold: Tested with Penicillium citrinum NBRC 6352, 60 minutes -Pollen: Tested with Cedar Pollen extract, 30 minutes

*** Tested with influenza_A (H1N1) and Staphylococcus aureus on Coway's GreenHEPA filter media by Japan Food Research Laboratories (JFRL) and no growth was found on the material after 24 hours kept in room temperature. → Both tests were performed on small test pieces cut from the Green HEPA filter media, so this disclaimer can be used for any Coway products that use this filter. -Virus: Tested with influenza_A (H1N1) , 3cm x 3 cm autoclaved piece – Bacteria: Staphylococcus aureus, inoculated on 50mm x 50mm test piece.

¹ The room size is calculated according to the NRCC-54013 standard. The CADR is tested in accordance with GB / T18801-2015. – NRCC (National Research Council Canada): Method for testing air purifiers – Formula for room size: Room size = 0.26 * CADR

² The CADR (Clean Air Delivery Rate) of particles is tested in accordance with GB / T18801-2015 by a certified third-party laboratory. – The measurement specifications are defined in GB / T 18801-2015, according to which two particle concentration decay rates have to be determined within a test chamber with a defined volume (Vchamber): a natural decay rate with an inactive air filter (knat) and a decay rate that occurs when measured in a 30 ㎥ test chamber is carried out. Except for the air filter placed on a table, this test chamber is empty. Two fans mix and circulate the air. In addition, there are a few measuring devices (mainly hoses) in this chamber. The chamber is kept at a temperature of 25 (± 2 ° C) and a relative humidity of 50 (± 10%). Cigarette smoke is used as the test aerosol and the number of particles> 0.3 µm is measured using an optical aerosol spectrometer using the indoor air filter (kAC). The decay rates “k” are determined from the measured decay of the particle concentration C (t) over time based on the initial concentration C0:

The test results may vary depending on the actual usage environment of the customer.